IMPORTANT: Observe all governing codes and ordinances.
(Please consult with a qualied electrician for 220-Volt 50 Hz voltage)
It is the customer’s responsibility:
To contact a qualied electrical installer.
To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/
NFPA 70 latest edition*, or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22. 2 No.
0-M91 - latest edition** and all local codes and ordinances.
If codes permit and a separate ground wire is used, it is recommended that a qualied electrician determine that
the ground path is adequate.
A 120-Volt, 60 Hz, AC-only, fused electrical supply is required on a separate 15-amp circuit, fused on both sides
of the line.
DO NOT ground to a gas pipe.
Check with a qualied electrician if you are not sure that the range hood is properly grounded.
DO NOT have a fuse in the neutral or ground circuit.
IMPORTANT: Save this Installation Guide for electrical inspectors use.
The range hood must be connected with copper wire/plug only.
The range hood should be connected directly to the fused disconnect (or circuit breaker) box through exible
armored or non-metallic sheathed copper cable. A U.L. - or C.S.A. - listed strain relief must be provided at each
end of the power supply cable.
Wire sizes (copper wire only) and connections must conform with the rating of the appliance as specied on
the model/serial rating label. Wire sizes must conform to the requirements of the National Electrical Code
ANSI/NFPA 70 latest edition*, or CSA Standards C22. 1-94, Canadian Electrical Code Part 1 and C22.
2 No. 0-M91 - latest edition** and all local codes and ordinances. A U.L. - or C.S.A. - listed conduit con-
nector must be provided at each end of the power supply cable (at the range hood and at the junction box).
Copies of the standards listed may be obtained from:
* National Fire Protection Association ** CSA International
Batterymarch Park 8501 East Pleasant Valley Road
Quincy, Massachusetts 02269 Cleveland, Ohio 44131-5575
Page 8
Electrical Requirements
Ductless Conversion
Ductless conversion is intended for applications where an exhaust duct work is not possible to be installed.
When converted, the hood functions as a purifying hood rather than an exhaust hood. Fumes and exhaust
from cooking is drawn and ltered by a set of charcoal lters. The air is then puried and re-circulated back
within the home.
We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct
work, if possible. Only when the exhaust option is not possible should you recourse to converting the hood
into a purifying unit.
When converted to be a “purifying” unit, a set of charcoal lters and an air-diverter are required in addition to
its standard aluminum lter set. Available at your local resellers. The standard aluminum lters are intended
to capture residue from cooking, the optional charcoal lters help to purify fumes exhausted from cooking,
and the optional air-diverter redirects ltered clean air back to the house.