Venting Methods
Page 7
IMPORTANT:
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or •
garages. All exhaust must be ducted to the outside.
Use metal/aluminum duct work only. •
Fasten all connections with sheet metal screws and tape all joints with certied Silver Tape or Duct Tape.•
Use caulking to seal exterior wall or roof opening around the cap.•
Venting Methods:
Vent work can terminate either through the roof or wall. To vent through a wall, a 90° elbow may be needed.•
This range hood is factory set for vertical venting using round or rectangular vent adapter but can be con-•
verted to horizontal venting by swapping the round vent adapter on top with rectangular vent adapter behind
the range hood as shown below:
Vertical roof venting
Roof cap
Option 2:
Side wall cap
Recirculate venting
Option 1:
Type 3:
6-inch round vent adapter on top
of the range hood.
Type 2:
3-1/4 x 10-inch rectangular vent
adapter on top of the range hood.
Type 1:
3-1/4 x 10-inch rectangular vent
adapter behind the range hood.
Option 3:
Horizontal wall venting
(available with 2000 Class only)
NOTE: The charcoal lters are preinstalled if you purchased the range hood with re-circulating kit from us.
Remove aluminum lters on hood.1.
Position the charcoal lter onto the motor and turn until it locks. Re-install aluminum lters.2.
Charcoal lters must be replaced after 120 hours of use (or approximately every 2 to 3 months based on the 3.
average of 1 to 2 hours of daily cooking time). Available at your local resellers.
Charcoal Filter Installation
Comments to this Manuals