Cavaliere UC200-1830S Use and Care Manual Page 9

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 8
Venting Methods
Page 7
IMPORTANT:
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or
garages. All exhaust must be ducted to the outside.
Use metal/aluminum duct work only.
Fasten all connections with sheet metal screws and tape all joints with certied Silver Tape or Duct Tape.
Use caulking to seal exterior wall or roof opening around the cap.
Venting Methods:
Vent work can terminate either through the roof or wall. To vent through a wall, a 90° elbow may be needed.
This range hood is factory set for vertical venting using round or rectangular vent adapter but can be con-
verted to horizontal venting by swapping the round vent adapter on top with rectangular vent adapter behind
the range hood as shown below:
Vertical roof venting
Roof cap
Option 2:
Side wall cap
Recirculate venting
Option 1:
Type 3:
6-inch round vent adapter on top
of the range hood.
Type 2:
3-1/4 x 10-inch rectangular vent
adapter on top of the range hood.
Type 1:
3-1/4 x 10-inch rectangular vent
adapter behind the range hood.
Option 3:
Horizontal wall venting
(available with 2000 Class only)
NOTE: The charcoal lters are preinstalled if you purchased the range hood with re-circulating kit from us.
Remove aluminum lters on hood.1.
Position the charcoal lter onto the motor and turn until it locks. Re-install aluminum lters.2.
Charcoal lters must be replaced after 120 hours of use (or approximately every 2 to 3 months based on the 3.
average of 1 to 2 hours of daily cooking time). Available at your local resellers.
Charcoal Filter Installation
Page view 8