Page 8
Electrical Requirements
IMPORTANT: Observe all governing codes and ordinances.
(Please consult with a qualied electrician for 220-Volt 50 Hz voltage)
It is the customer’s responsibility:
To contact a qualied electrical installer.
To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/
NFPA 70 — latest edition*, or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22. 2 No. 0-M91
- latest edition** and all local codes and ordinances.
If codes permit and a separate ground wire is used, it is recommended that a qualied electrician determine •
that the ground path is adequate.
A 120-volt, 60 Hz, AC-only, fused electrical supply is required on a separate 15-amp circuit, fused on both •
sides of the line.
Do not ground to a gas pipe.•
Do not have a fuse in the neutral or ground circuit.•
RISK OF ELECTRICAL SHOCK. This range hood must be properly grounded. Check with a qualied elec-•
trician if you are not sure whether the range hood is properly grounded.
The range hood should be connected directly to the fused disconnect (or circuit breaker) box through exible •
armored or non-metallic sheathed copper cable. A U.L. - or C.S.A. - listed strain relief must be provided at
each end of the power supply cable. Do not use extension cord or adapter plug with this appliance.
The range hood must be connected with copper wire/plug only.•
Always use plug provided. If not •
possible, connect three wires ac-
cording to its color (black to hot,
white to neutral, and green to
ground) to house wires and cap
with wire connectors:
Wire sizes (copper wire only) and connections must conform with the rating of the appliance as specied on
the model/serial rating label. Wire sizes must conform to the requirements of the National Electrical Code
ANSI/NFPA 70 — latest edition*, or CSA Standards C22. 1-94, Canadian Electrical Code Part 1 and C22.
2 No. 0-M91 - latest edition** and all local codes and ordinances. A U.L. - or C.S.A. - listed conduit con-
nector must be provided at each end of the power supply cable (at the range hood and at the junction box).
Copies of the standards listed may be obtained from:
* National Fire Protection Association ** CSA International
Batterymarch Park 8501 East Pleasant Valley Road
Quincy, Massachusetts 02269 Cleveland, Ohio 44131-5575
Charcoal Filter Installation
White
Green
Black
NOTE: The charcoal lters are preinstalled if you purchased the range hood with re-circulating kit from us.
Remove stainless steel bafe lters on hood.1.
Remove the safety lter under the stainless steel bafe lters by unscrewing two screws, then position the 2.
charcoal lter and align the screw holes, reinstall and fasten two screws.
Reinstall the stainless steel bafe lters back to the hood.3.
Charcoal lters must be replaced after 120 hours of use (or approximately every 2 to 3 months based on the 4.
average of 1 to 2 hours of daily cooking time). Available at your local reseller.
Comments to this Manuals