Page 13
Controls:•
Adjusting the timer function:•
While the blower (motor) is not running, press and hold • Decrease Value button over 3 seconds to
enter timer mode. Adjust to desired period of delay off timer by pressing Increase Value or Decrease
Value button (minimum 1 minute to maximum 9 minutes). This setting will be saved immediately.
Activating the timer function:•
While the blower (motor) is running, press and hold • Power button for over 3 seconds to activate
delay off timer. Power-Off Delay Digital Timer begin to countdown, when it reaches zero, the blower
(motor) will shut down.
Adjusting the light:•
Press • Light button once to turn on the lights, and once again to turn off the lights.
While the lights are off, press and hold • Light button for over 3 seconds to dim the lights from high to
low. Level of brightness will be stored in system’s memory.
CAUTION: DO NOT touch the lights until switched OFF and cooled.
Note: Light settings are independent from other settings (including power-off delay) and lights has to be
manually turned on or off.
Note: The system saves user congurations, settings such as light, timer and blower (motor) speed will re-
main the same the next time it is turned on.
Range Hood Operations (Continued)
Power
Power-Off Delay
Decrease Value
Light
Increase Value
Blower Speed Indicator
Power-Off Delay Digital Timer
Cleaning Reminder Indicator
Comments to this Manuals